Physical Properties of EPS

Specification Reference (ASTM-C578-95) Type I
(1#)
Type VIII
(1 1/4#)
Type II
(1 1/2#)
Type IX
(2#)
Property: Units ASTM Test  
Density, Min. (pcf) C303 or
D1622
  0.90 1.15 1.35 1.80
Thermal Conductivity
"K Factor"
BTU/(hr)
(sqft)(°F/in)
C177 or
C518
@ 25 °F  0.238 0.227 0.217 0.208
@ 40 °F 0.250 0.238 0.227 0.217
@ 75 °F 0.277 0.263 0.250 0.238
Thermal Resistance
"R Value"
One inch
thickness
C177 or
C518
@ 25 °F 4.20 4.40 4.60 4.80
@ 40 °F 4.00 4.20 4.40 4.60
@ 75 °F 3.60 3.80 4.00 4.20

Strength Properties Type I
(1#)
Type VIII
(1 1/4#)
Type II
(1 1/2#)
Type IX
(2#)
Property: Units ASTM Test  
Compressive
@ xx% deflection
psi D1621 @ 1/2% 3.5 4.3 6.0 8.0
@ 1% 7.0 8.5 12.0 16.0
@ 5% 8.0 11.0 12.0 20.0
@ 10% 10.0 13.0 15.0 25.0
Flexural psi C203   25 32 40 55
Tensile psi D1623   16 17 18 23
Shear psi D732   18 23 26 33
Shear Modulus psi ---   280 370 460 600
Modulus of Elasticity psi ---   180 250 320 460
Allowable
Compressive
Stress
psi . Long-Term Load 2.1 3.3 4.5 7.0
Short-Term Load 4.0 5.0 5.9 9.1
Rolling Loads 8.0 10.0 11.8 18.2
Young's modulus psi . . 573 739 1000 1449
Modulus of
Subgrade
Reaction
[k],pci . . 200 240 280 460
Poisson's Ratio [v] . . .086 .103 .126 .165
Coefficient of
Friction
. . . 0.5-0.7 0.5-0.7 0.5-0.7 0.5-0.7

Moisture Resistance Type I
(1#)
Type VIII
(1 1/4#)
Type II
(1 1/2#)
Type IX
(2#)
Property: Units ASTM Test  
Water Vapor Permeance,
max. perm.
Perms
(ng/Pa•s•m²)
E 96 . 5.0
(287)
3.5
(201)
3.5
(201)
2.0
(115)
Absorption by Volume, max. % C272 . < 4.0 < 3.0 < 3.0 < 2.0
Capillarity --- --- . None None None None
Buoyancy lbs/ft³ . . 60 60 60 60

Other Properties Type I
(1#)
Type VIII
(1 1/4#)
Type II
(1 1/2#)
Type IX
(2#)
Property: Units ASTM Test  
Coeff. of Thermal Expansion in./(in) (°F) D696  . 0.000035 0.000035 0.000035 0.000035
Max. Service Temperature °F ---  Long-Term  167 167  167  167 
 Intermittent 180 180 180 180
Flame Spread   max.  6"   UL® (BRYX)    20 20 20 20
Smoke Development   UL® (BRYX)   300 300 300 300

All values based on data from Huntsman Chemical Corporation, Styrochem International, NOVA Chemical Corporation and BASF Corporation.

Federal Trade Commision Ruling: Use the 75 F R-Value when calculating R-Values for residential construction.

Design Considerations:
  • DO NOT COMPARE polyisocyanurate conditioned R-Values by RIC-TIMA and PIMA to EPS R-Values by ASTM C-578.
  • ASK for a 20 year 100% R-Value Warranty.
  • Flammability: Like many construction materials, EPS is combustible.  It should not be exposed to flame or other ignition sources.  Current model building code requirements should be met for adequate protection or seperation from occupied areas.
  • Water Absorption Properties: EPS water absorption is low.  Moisture takes the path of least resistance and travels around individual beads rather than through them; the non-interconnecting cell structure prevents capillary absorption.
  • Water Vapor Transmission: EPS has low permeability but is not considered a vapor barrier.